Fire-Resistant Fabric Wrapped Acoustic Panel
Commercial interiors often need acoustic treatment without introducing an industrial-looking surface. The LEEYIN Fire-Resistant Fabric Wrapped Acoustic Panel provides a soft textile finish while helping control reflected sound and reverberation within cinemas, auditoriums, offices, meeting rooms and public interiors.
Project teams can use the panels as a regular wall grid, a color-block installation or a custom geometric feature. Buyers comparing different materials can also explore the complete acoustic panel range.

Fabric Surface and Glass-Wool Construction
The panel is constructed with an acoustically transparent fabric or perforated-leather face over a centrifugal glass-wool core. The product data sheet lists a core density of 110 kg/m³ and core thicknesses of 25 and 50 mm. A white fiberglass-tissue layer is applied to the rear surface.
The permeable finish allows sound energy to enter the porous core instead of being reflected directly back into the room. This makes the panel suitable for managing reverberation and improving the acoustic character of occupied spaces. It is an absorptive interior finish rather than a complete sound-isolation wall system.
Solid colors and pattern-transfer finishes are available from the product finish collection. Physical samples should be approved before production to confirm the fabric weave, color, printed pattern and edge appearance. Project teams can request fabric and color samples during product selection.
Tested Acoustic Performance
A 1200 × 600 × 50 mm non-formaldehyde fabric wrapped acoustic panel achieved NRC 0.95 in Report No. LCA-JC-2020-02304. Fourteen panels were installed in a Type E mounting assembly with sealed joints and a 100 mm cavity behind the panels.
The test followed ISO 354:2003, which specifies reverberation-room measurement of sound absorption for materials used as wall or ceiling treatments.
A separate 25 mm, 80 kg/m³ fabric panel was tested over a 50 mm air space. This assembly achieved αw 0.60(H) and Sound Absorption Class C according to ISO 11654:1997.
Acoustic ratings apply only to the tested panel and mounting configuration. Core thickness, density, cavity depth, backing, installation method and treated surface area can affect project performance. Review the available acoustic test reports before using a value in a project specification.
Sizes, Colors and Custom Shapes
The product data sheet lists panel lengths of 600, 1200 and 2400 mm and widths of 600 or 1200 mm. The available combination should be confirmed when ordering.
In addition to rectangular panels, the product data sheet illustrates parallelogram, hexagonal, circular and triangular formats. These options allow architects to create modular patterns, feature walls, directional layouts and multi-color compositions.
For custom production, provide:
- Dimensioned wall elevations
- Required panel dimensions and thickness
- Fabric or perforated-leather selection
- Color or pattern reference
- Required geometric shapes
- Panel quantity
- Acoustic performance target
- Applicable fire-performance requirements
- Installation substrate and wall construction
Learn more about custom acoustic panel options for drawing-based projects.

Frequently Asked Questions
What is a fabric wrapped acoustic panel?
A fabric wrapped acoustic panel is a porous sound-absorbing core covered with an acoustically transparent textile. The surface allows sound to enter the core, helping manage reflected sound and reverberation inside the room.
What NRC does the panel achieve?
A tested 1200 × 600 × 50 mm configuration achieved NRC 0.95 when installed in a Type E assembly with a 100 mm cavity. This rating applies to the tested construction and should not be generalized to other thicknesses or mounting methods.
Which thicknesses are available?
The product data sheet lists 25 and 50 mm centrifugal glass-wool core options. Select the thickness according to the required wall depth, installation system, acoustic target and applicable project documentation.
Can the panel size and color be customized?
Yes. Listed options include solid colors, pattern-transfer finishes and several geometric formats. Custom dimensions can also be reviewed from project drawings. A physical finish sample is recommended before bulk production.
Does the product have fire-performance options?
The product data sheet lists different fire-performance constructions. The applicable classification depends on the selected face, core, backing and complete assembly. Request the corresponding product-specific report before adding a classification to the project specification.
How is the panel installed?
The supplied installation concept uses light-gauge steel framing, acoustic infill, plywood strips and dedicated panel clips. Final fixing details should be confirmed for the project substrate and approved wall construction.
Can I request samples and test reports?
Yes. You can request material and color samples and review the available acoustic test reports before approving the final product construction.
Typical applications include:
- Cinemas and screening rooms
- Auditoriums and performance spaces
- Meeting and conference rooms
- Offices and reception areas
- Corridors and public interiors
- Classrooms and lecture rooms
- Studios and media rooms
- Hotels, restaurants and clubs
- Modular acoustic feature walls
| Product Attribute |
Specification |
| Product Name |
Fire-Resistant Fabric Wrapped Acoustic Panel |
| Product Type |
Fabric acoustic wall panel |
| Face Material |
Acoustically transparent fabric or perforated leather |
| Core Material |
Centrifugal glass wool |
| Core Thickness |
25 or 50 mm |
| Listed Core Density |
110 kg/m³ |
| Backing |
White fiberglass tissue |
| Face Thickness |
0.40 mm |
| Backing Thickness |
0.20 mm |
| Listed Lengths |
600, 1200 or 2400 mm |
| Listed Widths |
600 or 1200 mm |
| Shape Options |
Rectangle, parallelogram, hexagon, circle and triangle |
| Colors |
Solid colors and pattern-transfer finishes |
| Tested NRC |
0.95 for the tested 50 mm Type E assembly with a 100 mm cavity |
| Additional Test Result |
αw 0.60(H), Class C, for a tested 25 mm, 80 kg/m³ Type E-75 assembly |
| Acoustic Test Method |
ISO 354:2003 |
| Installation |
Framed wall system with plywood strips and dedicated panel clips |
| Customization |
Dimensions, colors, patterns and geometric shapes |
| Brand |
LEEYIN |
Test report file
LYX16 Non-formaldehyde Fabric Wrapped Acoustic Panel-NRC 0.9
LYX15 25mm thick soft pack NRC test
The supplied installation system uses C- and U-shaped light-gauge steel framing with acoustic infill inside the wall build-up. Horizontal plywood strips are attached to the supporting structure, followed by dedicated panel clips that secure the fabric wrapped panels.
Vertical framing is shown at no more than 600 mm centers. Final strip dimensions, fixing spacing, fasteners and panel layout should be coordinated through an approved project drawing.
Before installation, check that the wall is dry, stable, clean and aligned. Set out the panel joints, color sequence, weave direction, corners and service openings before fixing the full wall area. Refer to the acoustic panel installation guidance for further project planning.